Command output filtering – HP Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem User Manual
Page 17

Introduction 17
3.
Enter a valid user name.
4.
Enter a valid password. The CLI command prompt appears.
5.
Enter commands for the Virtual Connect Manager.
6.
To terminate the remote access SSH session, close the communication software or enter exit at the CLI
command prompt.
To access the VCM CLI remotely through the Onboard Administrator CLI, run the connect interconnect
command from the Onboard Administrator CLI.
Command output filtering
The CLI provides output filtering capabilities that enable you to display only properties of interest. This feature
is useful for filtering large amounts of output data for specific information. One or more properties can be
specified in the output filtering rules.
The following examples illustrate some common usage scenarios for output filtering:
Example 1: Displaying all enabled users
->show user enabled=true
Example 2: Displaying all VC Ethernet modules
->show interconnect type=VC-ENET
Example 3: Displaying all external uplinks that have a link established
->show uplinkport status=linked
Example 4: Displaying all uplink ports with connector type of RJ-45 and speed configured to Auto
->show uplinkport type=RJ45 Speed=Auto
Example 5: Displaying all servers currently powered on
->show server power=On
- Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem Virtual Connect Flex-10.10D Module for c-Class BladeSystem Virtual Connect FlexFabric 10Gb24-port Module for c-Class BladeSystem Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem 4GB Virtual Connect Fibre Channel Module for c-Class BladeSystem Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem