User roles – HP Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem User Manual
Page 127

Command line 127
Item
Description
MinPasswordLength
(optional)
The minimum password length allowed for new passwords when adding a new
user and when changing an existing password. The default value is 8.
Examples
->set user-security StrongPasswords=Enabled
Enables strong user password enforcement
->set user-security StrongPasswords=Disabled
Disables strong user password enforcement
->set user-security MinPasswordLength=10
Modifies the minimum password length
Item
Description
show user-security Display general domain user security settings.
Syntax
show user-security
Example
->show user-security
Displays user security settings
vcm
Reset the Virtual Connect Manager.
Supported actions: help, reset
Item
Description
reset vcm
Reset the Virtual Connect Manager. A failover to the backup VCM can also
be specified (optional), if a backup VCM is available.
IMPORTANT: Resetting the VCM causes a temporary loss in connectivity with
the Virtual Connect Manager. If failover is specified and a backup VCM
exists, users are logged off and must reconnect using the backup VCM IP
address.
Syntax
reset vcm [-failover]
Option
Failover
Forces a failover from the current primary VCM to the backup VCM.
Examples
->reset vcm
Resets the Virtual Connect Manager
->reset vcm -failover
Resets the Virtual Connect Manager and forces a failover to the backup
VCM (if available)
User roles
The following table lists required user roles for CLI commands.
Command
Element
Domain Network Server Storage All access
add
banner
X
—
—
—
—
enet-connection
—
—
X
—
—
fabric
—
—
—
X
—
- Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem Virtual Connect Flex-10.10D Module for c-Class BladeSystem Virtual Connect FlexFabric 10Gb24-port Module for c-Class BladeSystem Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem 4GB Virtual Connect Fibre Channel Module for c-Class BladeSystem Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem