beautypg.com

Authorize autosync – HP Integrity NonStop J-Series User Manual

Page 35

background image

Installation

HP AutoSYNC User’s Guide522580-017

2-7

Authorize AutoSYNC

The following is displayed in the EMS log:

Appendix A, Operations and Management

describes further details on configuring and

determining the status of the monitor process.

Authorize AutoSYNC

To perform scheduled synchronizations, the ASYSYNCP process must be granted the
correct access rights. Authorization is the operation that confers these rights by
designating a user ID as the Authorizer. Only users that are “under” the Authorizer can
schedule synchronizations. See

The AutoSYNC Authorizer

on page 4-2 for details.

By default, the Authorizer is the user ID of the monitor process.

15:55 10JUN04 128,04,355 AutoSYNC Monitor $ZASY Starting Version
1.6.1 - 14SEP2004
15:55 10JUN04 128,04,355 AutoSYNC Monitor $ZASY Message
AutoSYNC License Information
Valid from date: None
Expiration date: Oct 15 2004
CPU model: Any
15:55 10JUN04 128,04,355 AutoSYNC Monitor $ZASY Message
AutoSYNC Global Settings
AutoSYNC ON
SYNCcompress OFF
SYNCrecover ON
SYNCoverIP OFF
SYNCTCPprocesses $ZTC0
EMSCollector $0
15:55 10JUN04 128,04,355 AutoSYNC Monitor $ZASY Started
15:55 10JUN04 128,04,355 AutoSYNC Monitor $ZASY SYNCUSER table cached.
Table entry count = 1.
15:55 10JUN04 128,04,355 AutoSYNC Monitor $ZASY Backup started, cpu 3
15:55 10JUN04 128,04,355 AutoSYNC Monitor $ZASY ASYSYNC process $X0423
started. User USER.SALLY, Dest
\SIERRA, Batch 0
15:55 10JUN04 128,04,355 AutoSYNC Monitor $ZASY ASYSYNC process $X0424
started. User USER.SALLY, Dest
\SIERRA, Batch 2
15:55 10JUN04 128,04,355 AutoSYNC Monitor $ZASY ASYSYNC process $X0425
started. User USER.SALLY, Dest
\SIERRA, Batch 3
15:55 10JUN04 128,04,355 AutoSYNC Monitor $ZASY ASYSYNC process $X0426
started. User USER.SALLY, Dest
\SIERRA, Batch 1
15:55 10JUN04 128,06,346 AutoSYNC ASYSYNC $X0426 Error 14 accessing
destination monitor \RSYS.$ZASY. User
DEVOF.JOHANNEC, Dest \RSYS, Batch 1
15:55 10JUN04 128,04,355 AutoSYNC Monitor $ZASY ASYSYNC process
\SYS.$X0426 stopped. User
DEVOF.JOHANNEC, Dest \RSYS, Batch 1

Note. 1.Internally, the default home terminal of the monitor is $ZHOME, as displayed by the
TACL command STATUS $process-name, because an EMS collector cannot be specified as
the home terrminal of a process when the process is started Functionally however, the home
terminal for the monitor process is the default EMS collector, as shown by the Autosync
STATUS MONITOR command.

2.The default EMS collector is $0, or the EMS collector configured by setting the global
parameter EMSCOLLECTOR.

This manual is related to the following products: