Command Interpreter

HP AutoSYNC User’s Guide522580-017

8-16

ADD SYNCFILESET

the start time of the synchronization window. The time is entered in the format
hour:minute:seconds between 00:00:00 and 23:59:59. The maximum window
is 24 hours.

When the START option is specified the INTERVAL is ignored and one
synchronization per day is performed at the start time.

If the start time is larger than the stop time, then it is assumed the
synchronization window crosses into the next day. If STOP is omitted, the
synchronization occurs once a day at start time. In this case the INTERVAL
option is ignored.

STOP hh:mm:ss

the ending time of the synchronization window. The time is entered in the
format hour:minute:seconds between 00:00:00 and 23:59:59. The maximum
window is 24 hours.

If the stop time is smaller than the start time, then it is assumed the
synchronization window crosses into the next day.

If STOP is omitted but START is specified, synchronization happens once a
day at the specified START time.

SUSPEND

the file set should be added to the synchronization schedule without activating
it.

The user can subsequently activate the file set using the ACTIVATE
SYNCFILESET command.

TIMEEX[ACT]

that a file is synchronized if the modification timestamp of the source does not
exactly match the modification timestamp of the destination file.

By default, a file is synchronized only when the source file has been modified
after the destination file was last modified. The comparison of timestamps
accounts for differences in system clocks and time zones..

Note on symbolic links.

Because source and destination modification

timestamps of symbolic links never match, TIMEEXACT is ignored if specified
for symbolic links. For further details on symbolic link synchronization, see
paragraph

Modification Timestamp of Symbolic Links

on page 5-4

Note on SQL Shorthand Views.

A SQL view has no modification timestamp.

Instead AutoSYNC uses creation timestamps. This prevents a shorthand view
from being synchronized every time the file set is synchronized.
However if TIMEEXACT is specified, the shorthand view will always be
synchronized because the creation time of the destination is always newer
than the creation time of the source. For further details on SQL View
synchronization, see paragraph

SQL Views

on page 3-8

.