HP Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem User Manual
Page 26

Troubleshooting 26
Error code
Details
VCSU_ERROR_ROLLBACK_DOWNGRADE_WILL_NOT_
PROCEED_FOR_SERVERPOWERON_NOSAFE
Powered ON servers or server profile migration
since upgrade and performing downgrade may
result in duplicate MAC/WWN in the domain.
Power OFF the servers to avoid the
MAC/WWN duplication and perform the
downgrade.
VCSU_ERROR_ROLLBACK_FAILED_TO_ACTIVATE_
LOWEST_BAY
Failed to activate lowest E-net bay for rollback
VCSU_ERROR_ROLLBACK_FAILED_TO_ACTIVATE_ODDSIDE
_MODULE
Failed to activate odd side modules for rollback
VCSU_ERROR_ROLLBACK_ACTIVATE_FAILURE
Rollback activation failed
VCSU_ERROR_ROLLBACK_ODDMODULE_MANAGED_
STATUS_NOT_NORMAL
Odd module managed status is not Normal.
VCSU_ERROR_ADD_USER_FAILED
Unable to add user
VCSU_ERROR_REMOVE_USER_FAILED
Unable to remove user
VCSU_ERROR_SET_NAME_FAILED
Unable to set the user name
VCSU_ERROR_AND_EXIT_FROM_UPDATE
Fatal error. One or more modules is preventing
VCSU from continuing. Correct conditions listed
above and retry.
VCSU_ERROR_MODULE_FAILOVER_FAILED
Module did not come up with proper role after
failover.
VCSU_ERROR_FIRMWARE_EXTRACT_FAILED
Failed to extract the VC firmware package
VCSU_ERROR_GET_ENCLOSURE_INFORMATION_FAILED
Failed to get enclosure information
VCSU_ERROR_SET_TO_SLAVE_FAILED
Failed to set the module to subordinate state
VCSU_ERROR_SET_TO_AUTO_FAILED
Failed to set the module to auto state
VCSU_ERROR_VC_LOGIN_FAILED
Failed to log in to Virtual Connect
VCSU_ERROR_ADD_VCM_USER_FAILED
Failed to add VC user in Onboard
Administrator
VCSU_ERROR_PRIMARYMODULE_BEING_IN_EVENBAY_
AND_NO_BACKUP_MODULE
Rollback will not proceed since primary module
is in even bay and there is no backup module.
VCSU_ERROR_RESOLVE_HOST_INFO_FAILED
Failed to resolve the hostname
VCSU_ERROR_VCM_SKIP_FAILOVER
Virtual Connect does not have a valid Backup
module. Cannot failover.
VCSU_ERROR_DISCOVER_MODULES_FAILED
Failed to discover the Virtual Connect modules
VCSU_ERROR_INVALID_OA_ADDRESS
Invalid Onboard Administrator IP Address
VCSU_ERROR_INVALID_VCM_ADDRESS
Invalid Virtual Connect Manager IP Address
VCSU_ERROR_WRITE_OPERATION_FAILED
Failed to write into the file
VCSU_ERROR_VCM_AUTHENTICATE_FAILED
Virtual Connect Manager authentication failed.
VCSU_ERROR_UNSUPPORTED_FIRMWARE_MODE
The firmware mode of the VCEM Domain
Group is not supported by the firmware
package.
VCSU_ERROR_DOMAIN_INVALID_CONFIGURATION
Onboard Administrator VCMODE is not
correct. Log into Virtual Connect Manager and
reestablish credentials, and retry Virtual
Connect Support Utility.
VCSU_ERROR_NO_ENET_MODULES
There are no VC-Enet modules in the domain.
VCSU_ERROR_SSH_SCP_WRITE_FAILED
The SCP write failed
VCSU_ERROR_FC_UPDATE_FAILED
Failed to update the FC module
- Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem 4GB Virtual Connect Fibre Channel Module for c-Class BladeSystem Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem Virtual Connect FlexFabric 10Gb24-port Module for c-Class BladeSystem