beautypg.com

Target login problems, Boot problems, Lun access problems – HP NC374m PCI Express Dual Port Multifunction Gigabit Server Adapter User Manual

Page 21: Os problems

background image

Troubleshooting 21

Target login problems

Symptoms:
The iSCSI initiator is able to connect to the target but is unable to log in successfully.

Possible causes:

The initiator is not configured with the right target name

The initiator is not configured with the right target IP address

The initiator is not configured with the right initiator name

The initiator and target are not configured for the same authentication method

The initiator and target are using CHAP or Mutual CHAP authentication so they may not be

configured with matching user name and secret(s)

If the target implements some form of Access Control Lists (ACL), the target may not be configured to

allow it on the initiator

Boot problems

Symptoms:

The initiator is able to connect to and log in to the target, but the system does not attempt to boot from the

iSCSI disk.

Possible causes:

Verify the Standard Boot Order (IPL) list and Boot Controller Order list is configured correctly in

RBSU according to the Configure the server for iSCSI boot section.

Option ROM space is limited. If too many option ROMs are enabled the boot may fail due to lack of

space. In this case it is necessary to disable PXE on other adapters, disable the Smart Array

Controller, physically remove the hard drives, and so on.

Verify the Option ROM configuration setting "Boot to iSCSI" is set to Enabled.

LUN access problems

Symptoms:

The initiator is able to connect to and log in to the target, but the system doesn't see a disk present (it

attempts to boot from an internal disk or PXE).

Possible causes:

The initiator is not configured with the correct LUN from which to boot (Some targets start numbering

at 1 instead of 0)

The target is not configured to allow access to the specified LUN by the initiator

OS problems

Symptoms: