Server management 54


7.

Start connection by clicking the phone icon on the HyperTerminal toolbar.

8.

Press Esc once, then press Shift + 9.
This will switch the COM port mode from System to CLI.

9.

Log in to system BMC by entering the user name (admin) and password (admin).
To illustrate, to change to map1 directory, type cd map1 to change directory to map1.

/./-> cd map1

/./map1/->

KCS command line interface

This interface allows the user to access the ProLiant server by booting it into DOS.

To access the KCS command line interface:

1.

Follow the HP standard procedures for turning on the system, but in this instance use DOS to boot it.

2.

Change directory (CD command) to the directory where the IPMITOOL program or a similar IPMI utility is

located.
The examples below are based on the IPMITOOL program.

3.

Run the IPMITOOL and observe the command sequence according to the IPMI specification.
To illustrate, set the BMC COM port to 01.

(Write) ipmitool 20 30 10 04 C0 01

(Return)20 34 10 CE ---> Command Response could not be provided.

Check setting

(Read) ipmitool 20 30 11 04 C0 00 00

(Return)20 34 11 00 11 01 ---> Setting BMC COM port to 01 is OK.

Sensor readings are done through the following:

IPMITOOL 20 10 2d xx

CPU sensors

CPU0 Internal Error (Sensor# 0x57)

CPU1 Internal Error (Sensor# 0x58)

CPU0 Thermal Trip (Sensor# 0x55)

CPU1 Thermal Trip (Sensor# 0x56)

CPU0 Prochot (Sensor# 0x59)

CPU1 Prochot (Sensor# 0x5A)

CPU0 Socket Occupied (Sensor# 0x5B)

CPU1 Socket Occupied (Sensor# 0x5C)

CPU0 Thermal Diode (Sensor# 0x46)

CPU1 Thermal Diode (Sensor# 0x47)

CPU0 Fan1-4 (Sensor# 0x31,33,34,35)

Rear Fans (Sensor# 0x32,3C,3D,3E)

CPU0 Vcore Sense (Sensor# 0x3A)