Advanced chipset control submenu – HP ProLiant DL140 G3 Server User Manual
Page 10

System BIOS configuration 10
Advanced Chipset Control submenu
Figure 6 Advanced Chipset Control submenu
Table 6 Advanced Chipset Control submenu fields
Field Description
Options
SERR Signal Condition Select the ECC error condition that will prompt a SERR#.
None
Single Bit
Multiple Bit
Both
4 GB PCI Hole
Granularity
Select the granularity of PCI hole for PCI resource.
128 MB
256 MB
1.0 GB
2.0 GB
Memory Branch Mode Select the type of memory branch mode to employ.
Sequential
Interleave
Mirror
Single Channel 0
Branch 0/1 Rank
Interleave
If the Memory Branch Mode field is set as Interleave, select the interleave
mode to employ for the selected memory branch.
1:1
2:1
4:1
Branch 0/1 Rank
Sparing
Select whether to enable sparing for the selected memory branch.
Enabled
Disabled
Enhanced x8 Detection Select whether to enable the enhanced x8 detection function.
Enabled
Disabled
Enable Multimedia
Timer
Select whether to enable the system multimedia timer.
Yes
No
Parallel ATA
Select whether to enable support for PATA devices.
Enabled
Disabled
Serial ATA
Select whether to enable support for SATA devices.
If enabled, set options for the Native Mode and SATA Controller Mode fields.
Enabled
Disabled
Native Mode
Operation
Select the native mode for the SATA function.
Auto
Serial ATA
SATA Controller
Mode Option
Select whether to set SATA/PATA devices to legacy (Compatible) or native
(Enhanced) mode.
Compatible
Enhanced