HP Serveur lame HP ProLiant BL465c Gen8 User Manual
Page 449
8.
Transfer the temporary file to the database server.
Using
ftp
on database server B, transfer the temporary file from backup server B to database
server B:
BKServer B > ftp name-of-database-server-A
ftp> Username: (Enter the login name)
ftp> password: (Enter the password)
ftp> get 0000000013.drm
ftp> quit
BKServer B >
9.
Import the temporary file transferred from the backup server into the backup catalog on the
database server.
Execute the
drmdbimport
command on database server B to import the temporary file into the
backup catalog:
DBServer B > drmdbimport -f C:\0000000013.drm
KAVX0001-I The drmdbimport command will now start.
KAVX0418-I Backup information from the specified file was imported into the backup catalog.
Imported backup ID = 0000000012
KAVX0002-I The drmdbimport command will now end.
DBServer B >
10.
Confirm that the file was imported correctly.
Execute the
drmexgcat
command on database server B to check whether the backup catalog
information for the date that the backup was performed from the primary volume to the secondary
volume was performed has been imported on database server B:
DBServer B > drmexgcat
STRAGEGROUP: STR1
BACKUP-ID:0000000012 BACKUP-MODE: VSS STRAGEGROUP: STR1 ORIGINAL-ID:0000000011
START-TIME:2007/11/01 10:00:00 END-TIME: 2007/11/01 10:05:00 HOSTNAME:EXG_SRV1
T OBJECT INFORMATIONSTORE FILE FS DG DEVICE
COPY-GROUP
M MAILBOXSTORE MAILBOX1(STR1) D:\STR1\priv1.edb D: - Harddisk1
EXG003,B001
- - - - - - -
EXG003,B001
P PUBLICSTORE PUBLIC1(STR1) D:\STR1\pub1.edb D: - Harddisk1
EXG003,B001
- - - - - - -
EXG003,B001
T TRANSACT - E:\STR1\E00*.log E: - Harddisk2
EXG004,B001
- - - - - - -
EXG004,B001
C CHECKPOINT - E:\STR1\E00.chk E: - Harddisk2
EXG004,B001
- - - - - - -
EXG004,B001
DBServer B >
Application Agent CLI User Guide
449