beautypg.com

HP Ordinateur de jeu Compaq X07 User Manual

Page 4

background image

1.2 FREQUENCY

47Hz ~ 63Hz

1.3 CURRENT:

1.4 INRUSH CURRENT

115V/60A(max.), 230V/100A(max.) at 25°C cold start

1.5 POWER EFFICIENCY

68% (min.) at full load, 115/230Vac 60Hz/50Hz

2.0 OUTPUT:

Note:
1) The continuous maximum total output power

VOLTAGE

+5V

+12V

+3.3V

-5V

-12V

+5VSB

MAX. LOAD
TRUE330

30A

17A

28A

0.5A

1.0A

2.0A

TRUE380

35A

18A

28A

0.5A

1.0A

2.0A

TRUE430

36A

20A

28A

0.5A

1.0A

2.0A

TRUE480

38A

22A

30A

0.5A

1.0A

2.0A

TRUE550

40A

24A

32A

0.5A

1.0A

2.0A

MIN. LOAD

0A

0.8A

0A

0A

0A

0A

REGULATION

±3% ±3% ±3% ±5% ±5% ±5%

RIPPLE & NOISE 50 120 50 50 120 50
(mV)

2) Peak surge current: 15 sec max. Measurements shall be made with an

oscilloscope with 20MHz bandwidth. 10uF electrolytic capacitor parallel
0.1uF ceramic capacitor to simulate system loading to measure it.

3) At peak load +12V output regulation +/-10%.

2.1 HOLD-UP TIME: 20ms (minimum)

Test Condition: Full load. AC input 115V or 230V, 60Hz or 50Hz

2.2 LOAD TRANSIENT RESPONSE (STEP LOAD)

Step load changes up to 20% of full load, while other loads remains constant within the
rating. The load waveform shall be a square wave with the slope of the rise and fall at
1A/usec and the frequency shall be from 10Hz to 1 kHz. The DC output voltage will
stay within regulation during the step load changes.

2.3 OVERSHOOT

Overshoot at turn on or turn off shall be less than 10% of the nominal output voltage.

3.0 PROTECTION:
If the power supply latches into shutdown stage (when over current, over voltage or short circuit
protection is working), the power supply shall return to normal operation only after the fault has
been removed and PS-ON is reset for a minimum of 1 Second or remove AC power is removed
and re-applied.

3.1 OVER CURRENT PROTECTION

Overload currents applied to each tested output rail will cause output trip
before they reach or exceed 110% ~ 150% for testing purposes. Overload currents
should be ramped at a minimum rate of 10 A/s starting from full load.

3.2 OVER VOLTAGE PROTECTION

3.3 SHORT CIRCUIT PROTECTION

All output to GND.

4.0 TIME SEQUENCE:

T1 Turn On Time (500ms max.)
T2 Output Voltage Sequencing (20ms max.)
T3 Power Good Delay Time (100ms < t3 <500ms)
T4 Power Fail Delay Time (1ms min.)
T5 Power Good Hold-Up time (20ms min)

115V/230V(FULL LOAD): 1ms minimum

115V

230V

TRUE330

8A

4A

TRUE380

10A

5A

TRUE430 10A

5A

TRUE480 12A

6A

TRUE550 12A

6A

TOTAL MAX. +5V, +12V & +3.3V

OUTPUT

MAX. OUTPUT

TRUE330 330W

310W

TRUE380 380W

360W

TRUE430 430W

410W

TRUE480 480W

460W

TRUE550 550W

530W

SENSE LEVEL

OVER VOLTAGE

+5V

6.5V/max.

+12V

14.4V/max.

+3.3V

4.1V/max.

5

4