beautypg.com

Acer PCI Disk Array Controller Drivers 08P4100 User Manual

Page 78

background image

Installing the Mylex Disk Array Controller as the Primary UnixWare Controller with UnixWare 2.1.2

6-6

Manual No. 775079

6

U

N

I

X

W

A

R

E

Installing the Mylex Disk Array Controller as the
Primary UnixWare Controller with UnixWare 2.1.2

Mylex multifunction controllers use firmware 4.x or above. A special patch
is required for operation of these controllers with UnixWare 2.1.2 (not
required for UnixWare 2.1.3 or 7.x on x86). Follow the steps below to
download the patch files and create diskettes.

Note

If you are installing UnixWare 7.x or UnixWare 2.1.3
as a primary controller, please refer to “Installing the
Mylex Disk Array Controller as the Primary
UnixWare Controller with UnixWare 7.x/2.1.3” on
page 6-3.

1. Download the following files from the Technical Support area of the

Mylex web site:

ptf3256.boot.dd.exe

ptf3256.s.exe

2. Insert a non-bootable DOS-formatted floppy diskette in the diskette

drive and run:

ptf3256.boot.dd.exe a:

3. Remove the first diskette, then insert a second non-bootable

DOS-formatted floppy diskette in the diskette drive and run:

ptf3256.s.exe a:

Use the two diskettes you’ve just created when requested in the procedure
below.

To install the UnixWare driver for the Mylex Disk Array Controller:

1. Follow the instructions in the appropriate Mylex Disk Array Controller

manuals to set up the hardware, install the controller, connect the disk,
tape, and/or CD-ROM drives, and run the RAID EzAssist
Configuration Utility to create Drive Groups and System Drives.

Note

CD-ROM or tape drives may be connected to any