3. Choose “Configure disk and storage device drivers” in the Driver

Options menu.

4. Choose “Select an additional driver” in the Additional Driver Actions

menu.

NetWare scans for controllers that do not have drivers already loaded.

5. At the “Select a driver” box, press to choose to install an

unlisted driver.

6. Insert the DOS-formatted NT4/NW Drivers Software Kit diskette into

the diskette drive.

7. Press to specify the path of the NetWare driver you’re about to

install.

8. Change the path line to read:

A:\netware

and press . NetWare scans for drivers on the floppy diskette in
the specified path.

9. In the “Select a driver to install” box, select the appropriate driver for

your controller:

MDAC.HAM |

10. Select Yes at the confirmation box to install the driver.

11. Press to select the default server boot path.

12. Select Yes to save a backup of the old or existing driver.

13. Press to continue when you see the message that the old

driver will be saved.

NetWare copies the file.

14. What you just backed up was the old or existing .DSK or .HAM file.

Repeat Steps 12 and 13 for the .DDI file.

15. Select No to decline selection of an additional driver to install unless

you are installing more than one Mylex controller at this time.

16. Exit INSTALL.NLM by pressing three times, then selecting Yes

at the “Exit Install?” box.

This concludes installation of the driver files needed to run your Mylex Disk
Array Controller under NetWare 4.2.