beautypg.com

Installation – Electrolux EXM24HV1WE User Manual

Page 8

background image

8

Outdoor Unit installation

Drain-water

hole

Drain

connecter

Chassis

Hose of inner dia. 16mm

(not provided)

installation

Air inlet

Air inlet

Air outlet

• If a suspended installation is needed,

the installation bracket must allow the

fix according to dimensions on the

figure above.

• The wall where the unit will be installed

must be of solid brick, concrete or

provided with other reinforcement ways

to fix the bracket. The fixation of the

bracket to the wall and the bracket to

the air conditioner must be firm, steady

and leveled.

• Anchor the outdoor unit by fixing the 4 holes

existent in its based with 4 bolts and nuts of

10 mm tightly (not included).

Place the outdoor unit over a horizontal

concrete or rigid surface (never directly over

grass or land).

step 2: Outdoor Condensate Drainage

(only for heat pump model)

• During heating operation, the condensate and

defrosting water should be drained out reliably

through the drain hose.

• Install the outdoor drain connector in the drain-

water hole on the chassis of outdoor unit, and

attach the drain hose to the connector so that

the waste water formed in the outdoor unit can

be drained out.

• The drain-water hole must be plugged.

Whether to plug other holes will be determined

by the installer according to actual conditions.

• In case of a drain hose, the unit must be

installed on a base more than 3cm height.

step 1: securing of Outdoor Unit

step 1: installation of Mounting Plate

1 Fit the mounting plate horizontally on the wall

with five or more self-tapping screws (type

ST4x25, item 3 on page 3).

2 be sure that the mounting plate has been

fixed firmly enough to withstand about 60kg.

Meanwhile, the weight should be evenly shared

by every screw.

3 3 If the wall is made of brick, concrete or the

like, drill five (5) or more holes of 5mm diameter

in the wall. Insert clip anchor (item 2 on page 3)

for appropriate mounting screws.

4 The water tray’s outlet for the indoor unit is two-

way drainage design. During installation, the

indoor unit should slightly slant to water tray’s

outlet for smooth drainage of condenser water.
Fit the mounting plate and drill holes in the wall

according to the wall structure and correcponding

mounting points on the mounting plate.

(dimensions are in mm unless otherwise stated)

Cool Capacity (W/h)

Mounting Plate type

EXM09HV1WI

A

EXM12HV1WI

b

caution

This manual is related to the following products: