20

After confirming the above conditions,

prepare the wiring as follows:
• The screws which fasten the wiring to

the terminal block may come loose from

vibrations during transportation.

• Check and make sure all screws are well

fixed. Otherwise, it could cause burn-out

of the wires.

• Be sure the circuit capacity is sufficient.
• Ensure the starting voltage is maintained

at over 90% of the rated voltage marked

on the nameplate.

• Confirm that the cable thickness is

as specified in the power source

specification.

• Always install a Residual Current Device

(RCD) in wet or moist area.

• The following may be caused by voltage

drop: Vibration of a contactor, which will

damage the contact point, fuse blowing,

disturbance of the normal function of the

overload.

• The means for disconnection from a

power supply shall be incorporated in the

fixed wiring and have an air gap contact

separation of at least 3mm in each active

(phase) conductor.

Downward

slope

B. Check the drainage

• Carefully pour a glass of water on the

evaporator.

• Ensure the water flows through the drain

hose of the indoor unit without any leakage

and goes out the drain exit.

Drain hose

C. Drain piping

• The drain hose should

point downward for

easy drain flow.

step 10: Checking the Drainage

A. Open and lift the indoor unit front panel.

• Hold the lower part of the left and right sides

of the panel, pull it against you and lift it stops

with a full support from the bracket.

• Do not place drain piping as indicated below:

Panel

bracket

caution

Accumulated

drain water

Do not rise

Tip of drain

hose dipped

in water

Air

Space less

than 50mm

Water

leakage

Water

leakage

Water

leakage

Ditch