safety Precautions

step 9: Electrical installation

B. in cases where the outdoor unit is

installed below the indoor unit level:

• Wrap the piping, drain hose and connecting

cable from the down to up.

• Secure the wrapped piping along the exterior

wall using saddle or equivalent.

Electrical safety rules before starting the

installation:
1 A dedicated power supply circuit and breaker

should be provided

for the products which

are not supplied with a

service cord and plug

in accordance with

local electrical safety

regulations.

2 The circuit breaker must have the functions of

magnetic tripping and heat tripping to prevent

short circuit and overload.

3 The appliance shall be installed in accordance

with national wiring regulations.

4 A circuit breaker with proper capacity must be

installed according to the table below.

Seal small openings

around piping with a

gum type sealer.

Wrapping

Pipe

Drain hose

Connection

cable

Drain hose

Trap is required to prevent water

from entering into electrical parts.

C. in cases where the outdoor unit is

installed above the indoor unit level:

• Wrap the piping and connecting cable from

the down to up.

• Form a trap to prevent water from entering

the room.

• Secure the wrapped piping along the exterior

wall using saddle or equivalent.

5 In case of problems in power supply, the air

conditioner must not be installed before the

customer fixes the problem.

6 be sure the power supply matches the air

conditioner.

7 Ensure the live wire, neutral wire and

earth wire in the power socket are properly

connected.

8 Inadequate or incorrect electrical connections

may cause electric shock, fire or some

electrical parts to malfunction.

9 before performing any electrical work, turn off

the main power to the system.

Earthing Requirements
1 Air conditioner is type I electric appliance. The

unit must be reliably earthed and connected

to the special earth device by the qualified

electrician.

Seal small openings

around piping with a

gum type sealer

Trap

Trap

Drain hose

Cooling

Capacity

(w)

Circuit

Breaker

2600

10A

3500

16A

5000

25A

7000

25A