beautypg.com

Wiring, Jf-2med, Door 2 – Aiphone JF-2HD User Manual

Page 4: Door 1, Ps-1820, Ps-1810din

background image

- 4 -

English

Fr

a

n

ç

ais

Neder

lands

JF-2MED

OP

EL-9S

OP

IER-2

1 E

L1

C1

L2

C2

L1

L2

RY-3DL

JF-2MED

+

+

DC 18V

EL-9S

b1

b2

b3

D1

D2

E

EL-9S

PS18

OG(b1)
YE(b2)
GR(E)

L

BR(L)
RD(L)

PT

A1 A2

JF-DVF

JF-D

JF-DV

JF-DA

JF-DV

AIPHONE

AIPHONE

JF-DVF

AIPHONE

JF-DA

DOOR 2

A1 A2

JF-DVF

JF-DV

JF-DA

JF-DV

AIPHONE

AIPHONE

JF-DVF

AIPHONE

JF-DA

DOOR 1

PS-1820

100V - 240V -

50/60 Hz

230V AC

N

L

18V DC

2 A

PS-1810DIN

18V DC 1 A

IN 230V~ 50/60Hz

NL

1A - +

-

+

#2

#1

#2

#1

E

KS

FS

PK

E

b2

V -

b1

V +

(BR)
(RD)

[1]

[2]

[7]

[3]

[4]

[6]

(OG)

(YE)

(GR)

(YE)

(BR)
(RD)

(OG)

(BL)

(PR)
(GY)

(WH)

SW

SW

L
L

[5]

PT

2

NP

[1]

DC 18 V

-

+

2

P

2

NP

2

NP

2

NP

PT

Insert wires securely into each terminal as shown.

Master monitor station

Video door station

Optional call extension speaker IER-2

Power supply +, - (DC 18 V)

(Audio only)

Setting is required. (Refer to section 7-7)

Control external devices connected with release connector
and option connector.
[1] Door release output

Setting is required. (Refer to section 7-8)

(AC/DC 24 V, 0.5 A N/O dry closure contact)
Connect the brown and red wires from the release
connector to the door release (or to the RY-3DL as shown
in the wiring diagram).

[2] Options output

(AC/DC 24 V, 1.6 A N/O dry closure contact)

[3] Video signal output

(NTSC, 1 Vp-p/75

Ω) Wiring distance: 3 m

[4] Door release-linked entrance output
[5] Press-to-talk setting input

If the blue and white wires are shorted, press-to-talk will
not be operable.

[6] Foot switch input

Connect a commercially-available foot switch to the
purple and white wires (N/O dry closure contact).

[7] External sensor input

Setting is required. (Refer to section 7-9)

Release connector

Option connector

Door release

or

RY-3DL

RY-3DL

Input method

N/O dry closure contact
External sensor input
(start signal only detection method)

Detection confirmation time 100 mS or more
Contact resistance

During dry closure: Less than 700

Terminal short current

Less than 10 mA

Voltage between terminals

Less than DC 20 V
(when open between terminals)

To prevent shorts, be sure to cut unused lead wires
at the bottom and insulate the ends.

Door release EL-9S (AC 12 V, 0.35 A) or
equivalent, requires a separate AC transformer.
Run separate cables for audio/video and door
release.
Door release contact: AC/DC 24 V, 0.5 A
(N/O dry closure contact L, L).

Door release

Optional selective door release
adaptor RY-3DL
Use RY-3DL when connecting
door release to 2 locations.

OG: Orange
YE: Yellow
GR: Green
BR: Brown
RD: Red

Option connector

Release connector

WIRING

3

AC Transformer