Mounting – Aiphone JK-1MD User Manual

Page 4

background image

- 4 -

English

Fr

ançais

Español

Neder

lands

Italiano

3

MOUNTING

Back wiring

JK-1MD

1

2

UP

8 mm
(3/8")

1-gang box

83.5 mm
(3-5/16")

Mounting bracket

Mounting screws x 2

1. Press RELEASE button (to insert or

remove the wire).

2. Insert the cable into the terminal.

Surface wiring

* When a 1-gang box is not mounted, the cable can be routed as surface wiring to the top or bottom

of the unit. Cut a cable inlet on the upper part of the unit to allow passage of the wiring into the unit.

PS-1810DIN/

PS-1820DIN

PS-1820

Mounting bracket

1-gang box

Din rail

83.5 mm
(3-5/16")

UP

* To pass the cable through the rear

side of the unit, cut out a cable inlet
section.

83.5 mm
(3-5/16")

Mounting bracket

Wood
mounting
screws x 2

Option connector: Control external devices connected with the option connector.

[3]

BR: Brown

RD: Red

OR: Orange

YE: Yellow

GR: Green

BL: Blue

KE

KS

SW

SW

V -

V +

[1]

[2]

[3]

(BR)

(RD)
(OR)

(YE)

(GR)

(BL)

To prevent shorts, be sure to cut unused lead wires at the bottom
and insulate the ends.

[1]Video signal output: Video can be output to DVR, etc.

(NTSC, 1 Vp-p/75

) Wiring distance: 3 m (10')

NOTES: When a video signal is output, the monitor

station may produce a buzzing sound depending
on the installation environment.

A video signal is only output during calling from a door
station to the JK-1MD/during communication between a
door station and the JK-1MD/during monitoring from the
JK-1MD (screen playing recorded pictures is not output).

[2]Options output

(AC/DC 24 V, 1.6 A N/O dry closure contact)

(Minimum contact: 100 mV DC, 0.1 mA)

Press-to-talk setting: Press-to-talk can be set to be enabled or disabled.

Press-to-talk setting
Switch initial setting [ON]

ON: Press-to-talk enabled
OFF: Press-to-talk disabled

[3]External sensor input

External sensor input specifications

Input method

N/O dry closure contact
External sensor input (start signal only
detection method)

Detection confirmation time 100 mS or more

Contact resistance

During dry closure: Less than 700
During N/C dry closure: At least 3 k

Terminal short current

Less than 10 mA

Voltage between terminals Less than DC 20 V (when open between terminals)