beautypg.com

4 features, Figure 1 sbfc series technical specifications – Sterlco SBFC Series Blown Film Coolers User Manual

Page 8

background image

Page 8

SBFC Series Blown Film Cooling Systems

1-4 Features

• Bolt-on support legs
• Condensate trap
• Insulated heavy-gauge steel cabinet designed for up to 35”

(8.7 kPa) static pressure

• Dial thermometers for discharge air and chilled water

supply/return

• Air inlet and outlet adapters
• Copper tube aluminum fin chilled water cooling coil
• Insulated drip pan
• Permanent filter
• Choice of 230/3/60 or 460/3/60 operating voltages
• 1-year warranty on parts and labor

Optional

• Pre-piped automatic 3-way chilled water control valves
• Pre-piped automatic 2-way chilled water control valves; for

use only with a distributed chilling system, not with a
dedicated chiller

• Electric blower starters for field mounting
• Blowers, with High or Low Static Pressure

Figure 1

SBFC Series Technical Specifications

Optional blower motor

Shipping weights

16” (3.9 kPa) 35” (8.7 kPa)

with blower

Air flow

Die

static

static

Base

16” (3.9 kPa) 35”

(8.7 kPa)

rated

hp/kW maximum

dia. pressure

pressure

unit

static pressure static pressure

Model

no.

cfm

cmh

in. cm hp kW hp kW

lbs.

Kg lbs. Kg lbs. Kg

SBFC-600 600

1,019 5 12.7 3 2.24 7½

5.60

440

205 570 265

1,030 478

SBFC-1000 1,000 1,699 18

45.7

5

3.73 10

7.46 440

205

570

265 1,030

478

SBFC-1500 1,500 2,548 30

76.2

7½ 5.60 15

11.19 690

321

890

413 1,325

615

SBFC-2000 2,000 3,398 40

101.6

10

7.46 20

14.92 740

344

965

448 1,465

680

SBFC-3500 3,500 5,946 60

152.4

20

14.92 40

29.84 1,260

585 1,710

794 2,365 1,098

SBFC-5000 5,000 8,495 80

203.2

30

22.38 60

44.76 1,880

873 2,465 1,144 3,165 1,469

c Entering air @ 100ºF (38ºC) dry bulb, 80ºF (27ºC) wet bulb, 40ºF (4ºC) chilled water = 50ºF (10ºC) leaving air

temperature.