6 Troubleshooting

Problem Possible

cause Solution

Blower does not run.

No power.

Check main disconnect,
fuses, overloads, wiring and
power lead to unit. See
Figure 4 on Page 16.

Blower running in reverse.

Check rotation - reverse
motor leads.

Check for foreign matter or
restrictions.

Clean.

Variable voltage input.

Check for voltage variation
and deviation from name-
plate voltage. It should be
within 10% of the nameplate
voltage.

Dirty filter.

Clean the filter.

Blower does not deliver a
proper amount of air.

Blower undersized.

Check amperage input and
compare with nameplate
amperage of unit. CalI sales
representative.

Unit not cooling; high air
temperature.

Check for malfunction in the
chiller system.

Moisture carry-over
(external).

Check for condensation on
the air ring; insulate air ring
surfaces.
Restriction in the blower coil;
check for foreign matter and
clean. Check if unit is without
filter; install filter.
Partial freeze-up of the coil -
obstructing coil surface area.
Increase air temperature; see
Section 5-3 on pages 27-30.

Film bubble breaks.

Moisture carry-over (internal).

Obstruction of the conden-
sate drain. Check for proper
piping. Check for foreign
matter. Keep clean.