Specifications, Rm3100 evaluation board characteristics, Table 3-1: operating performance – PNI RM3100 Evaluation Board User Manual
Page 6: 3 specifications

PNI Sensor Corporation
Doc 1017252 r02
RM3100 Evaluation Board User Manual
Page 5 of 33
3 Specifications
3.1 RM3100 Evaluation Board Characteristics
Table 3-1: Operating Performance
1
Parameter
Cycle Counts
2
Units
50
100
200
Field Measurement Range
3
-800 to +800
T
Gain
20
38
75
LSB/ T
Sensitivity
50
26
13
nT
Noise
30
20
15
nT
Noise Density @ Max. Single-Axis Sample Rate
1.2
nT/ Hz
Repeatability over 200 T
15
8
8
nT
Hysteresis over 200 T
15
nT
Linearity over 200 T
0.5
%
Maximum Single-Axis Sample Rate
(divide by 3 for max. 3-axis sample rate)
1600
850
440
Hz
Single-Axis Average Current @ 24 Hz Sample
Rate (equivalent to 3-axis @ 8 Hz)
70
135
260
µA
Footnotes:
1. Specifications are typical and subject to change. Performance specifications established with 3.0
V supply voltage at room temperature.
2. The cycle count values (50 ,100, and 200) are user-configurable and set in the Cycle Count
Registers. See Section 5.1 for how to set the registers.
3. Field measurement range is defined as the monotonic region of the output characteristic curve.