5.2 Initiate Continuous Measurement Mode (0x01)

The RM3100 Evaluation Board can either take measurements automatically on a regular

frequency (Continuous Measurement Mode) or by polling for single measurement. This

section discusses Continuous Measurement Mode. See Section 5.3 for polling a single

measurement.

To initiate Continuous Measurement Mode, write to the CMM register address, 0x01,

followed by the CMM register contents. To set the rate of data acquisition in Continuous

Measurement Mode, see Section 5.2.1. Below are the contents of the CMM register.

Bit #

7

6

5

4

3

2

1

0

Value LDM CMZ CMY CMX DRDM1 DRDM0 ALARM START

Where:

START – A “1” in this bit position initiates Continuous Measurement Mode. To turn

off Continuous Measurement Mode it is necessary to write a “0” to this bit position.

Note that writing to POLL (i.e. initiating a single measurement command) while

operating in Continuous Measurement Mode results in the single measurement

command being ignored.

ALARM – A feature of the RM3100 Evaluation Board while operating in Continuous

Measurement Mode is the ALARM bit will go HIGH if a measurement reading is

outside a predefined range of values, set by the Alarm Upper and Lower Limit

Registers. This bit is set to ‘1’ if a limit is exceeded. The ALARM bit is reset by
writing a ‘0’ to this bit. See Section 5.2.2 for additional information.

DRDM – These two bits establish the required condition to trigger the DRDY pin to

HIGH. There are 4 possible conditions, as set out in Table 5-3.