2. playback modes – PATLITE FV-127JP User Manual
Page 19

- 19 -
The timing chart above indicates a message stopped during playback.
•
The timing duration between the input on and off can be no less than 10ms ( ※ ).
•
When the message starts playback, this is the case when no silence is added at the head of the message.
For pulse train details, refer to the individual playback modes.
( ☞ Refer to pg. 25 [7-2. Playback Modes])
The input delay time is set for 10ms. The input delay can be set for 50ms, for a 50ms delay.
7-2. Playback Modes
Settings for the following (A through E) playback modes are indicated below:
※
Settings made outside those indicated above will cause inoperability.
[Pulse Train]
O F F
1
2
3
4
5
6
7
8
Factory Settings
O F F
1
2
3
4
5
6
7
8
(B) Memory Playback
(A) Normal Playback
O F F
1
2
3
4
5
6
7
8
O F F
1
2
3
4
5
6
7
8
(E) Hold Playback
(D) Top Priority
Channel Playback
O F F
1
2
3
4
5
6
7
8
(C) Input Priority Playback
No less than 10ms
1 Channel Input
2 STOP (CLR)
3 Voice Message
4 Busy
500ms or less
10ms or more(*
1
)
10ms or more(*
1
)
260ms or less