- 15 -
5-2-6 Input Terminal Wiring
Connect each terminal through the COM terminal when wiring.
Use relays, switches or other non-voltage contacts or NPN open collector circuitry for operation.
Contact Capacity
Use the following table below to determine the capacity for external connections.
Voltage Capacity
15mA or more
Withstanding Voltage
DC35V or less
Leakage Current
0.1mA or less
"ON" Voltage (V
sat
)
1V or less
Do not connect any inputs to the power or output connections. Possible product failure may occur.
Contact capacity should always be fuse protected. Possible damage to contacts may occur.
10mA
Power Supply
FV-127JP
FV-127JP
External
Device
External
Device
COM
COM
Power Supply
Input
Input
Max. 29V
Max. 29V
10mA
SP-
SP+
AUX- AUX+ BUSY- BUSY+
24V
0V
FG
DEC2
DEC1
/VOL
COM
CH1
CH2
CH3
CH4
CH5
CH6
CH7
STB
CLR
STOP