Ouellet OWS User Manual
Page 5
5
1.1.
Technical features
Features
OWS-T
Type
Series heating cable set, twin conductor.
Voltage
240/208V, 347V
Mat width
24” (610 mm) and 36” (914 mm)
Linear density
12W/ft. (39W/m)
Density (3” [76 mm] spacing)
50W/sq. ft. (538W/sq. m) at 240V and 347V,
37.5W/sq. ft. (404W/sq. m) at 208V
Covered surface
6.5 sq. ft. (0.84 sq. m) to 126.7 sq. ft. (11.14 sq. m)
Cold lead length
16' 4'' (5 m)
Cold lead outer diameter
3/8” (9.5 mm)
Cold lead gauge
12 AWG or 14 AWG (according to maximum allowable load)
Minimum bend radius
1” (25 mm)
Heating cable diameter
1/4” (7 mm)
Resistance wire insulation
Fluoropolymer (ECTFE) 0.014” (0.35 mm) thick
Outer sheath insulation
Polyolefin (EPR) 0.08'' (2 mm) thick
Cold lead outer sheath insulation
PVC 0.03”(0.76 mm) thick
Ground
Braided copper shielding 17 AWG
Maximum long-term exposure
temperature
105 °C (221 °F)
Maximum exposure temperature
for 10 minutes
220 °C (428 °F)
Minimum installation temperature
-15 °C (5 °F)
Certification
Marking
Canada: WS, X
1
United States: Type C
Warranty (see Section 7)
10 years on heating cable
1
For outdoor embedded applications.
Resistance wires
Resistance wire insulation (fluoropolymer)
Braided copper shielding (ground)
Outer sheath insulation (polyolefin)
Ø
1/4''
7 mm
Figure 1: Cable cross-section