beautypg.com

Ouellet OWS User Manual

Page 13

background image

13

4.3.

Clearance and bypass distances

• Install heating cables at a minimum distance of 6” (152 mm) from the edge of the surface to be heated or from

an exterior wall.

Note: For embedding in asphalt (without curbs), install the heating cable at 12” (305 mm) from the edge.
• Install heating cables at a minimum distance of 6” (152 mm) from fixed elements.
Note: Plan for future elements which could be added afterwards (handrails, lampposts, etc...).
• Always maintain a minimum distance of 3” (76 mm) between heating cables.
• Install heating cables at a minimum distance of 0.5” (13 mm) from any uncovered combustible surface.
• To change directions or bypass obstacles, cut flexible strips and rotate the mat.
• To adjust cables to a smaller surface than the width of the mat, detach a suitable section of cable length from

the flexible strips to cover the surface to be heated.

• Cable runs must not exceed a 10’ (3 m) length.

6'' (152 mm) from the edge of the surface

12'' (305 mm) from the edge

of an asphalt coated surface without curb

6'' (152 mm) from fixed element

6'' (152 mm) from

exterior wall

180° change of direction

90° Change of direction

Detached cable

for small surface

Figure 5: Cable configuration and clearances

Never cross, overlap or bundle cables.

CAUTION!