Ouellet OWS User Manual
Page 15
15
4.5.
Installation of ground sensor conduit
9
Where heating cables are connected to the ET02 electric controller, a ground sensor (ETOG or ETOG-56) must be
installed to detect humidity and temperature.
For more information, please follow the manufacturer’s instructions supplied with the product.
• Install a conduit approved for ground sensor cable, at the same stage as installing the cold lead conduit, as
specified in installation guidelines (see Section 5).
Note: The ground sensor cable should be inserted in a separate conduit than that of the cold lead.
• Run the conduit between two heating cables. Do not cross, overlap or bundle the heating cables and
the ground sensor conduit.
• Position the ground sensor inside the heated surface, in an open location that will be subject to precipitations.
• If the ground sensor is installed on a slope, be sure to position the sensor so the top part is horizontal.
• Ground sensors should be installed once the surface coating has been laid.
9
Refer to the product catalogue for more information on available products.
Each option is supplied with an installation manual.
Conduit approved for
the ground sensor cable
Top of ground sensor horizontal
and level with the coating
Figure 8: Position of ground sensor