beautypg.com

NORD Drivesystems MI0300 User Manual

Page 20

background image

Decentralised drive technology - from SK 300E to SK 200E

20

Migration Guide-GB-11.10.2012

ASI:

Integrated AS interface

24V:

24V power supply

AGND:

Reference potential for analog signals

GND:

Reference potential for digital signals

DIN:

‚Digital input‘, digital output

DOUT:

‚Digital output‘, digital output

MB+/-: Control of electro-magnetic brake

(105V, 180V, 205V)

TF+/-:

Motor thermistor (PTC) connection

Fig. 6: Control terminals of the connection unit SK TI4-x-2xx-x-(C) for SK 2xxE

Connections and functions for SK 2xxE versions depending on configuration level

SK 200E

SK 220E

FI type

SK 205E

SK 225E

(ASI)

Labelling

(ASI)

Pin

24V (internal, output max. 200mA)

43

1

44

24V, external 24V FI supply

12

Analog input 1

ASI+, AS interface

14/84

2

44/84

24V, external 24V
FI supply

ASI+, AS interface

Analog input 2

16

3

40

GND, reference potential for digital
signals

AGND, Reference

potential for analog

signals

ASI-, AS interface

12/85

4

40/85

GND

ASI-, AS interface

DIN1 / digital input 1

21

5

21

DIN1 / digital input 1

DIN2 / digital input 2

22

6

22

DIN2 / digital input 2

DIN3, digital input 3

23

7

23

DIN3, digital input 3

DIN4, digital input 4

24

8

24

DIN4, digital input 4

GND

40

9

40

GND

DOUT1, digital output 1

1

10

1

DOUT1, digital output 1

GND

40

11

40

GND

10V Reference voltage

11

14

-

---

DOUT2, digital output 2

3

15

79

MB+, electromagnetic brake control

GND

40

16

80

MB-, electromagnetic brake control

TF+, motor PTC connection

38

17

38

TF+, motor thermistor (PTC) connection

TF-, motor thermistor (PTC) connection

39

18

39

TF-, motor thermistor (PTC) connection

Table 15: Overview of SK 2xxE control terminals

12

With the use of the AS interface, terminal 44 provides an output voltage (24V, max. 60mA). In this case, no

voltage source may be connected to this terminal!