Power and and control terminal connection – NORD Drivesystems MI0300 User Manual
Page 19
Power and and control terminal connection
19
More recent software files (GSD, EDS) are required for the field bus technology option SK TU4-xxx-
(C). Information about the master data for the device can be found in Section 5. Further software
planning information for conversion to the technology options for SK 2xxE frequency inverters can also
be found there.
3.2.1 Details of control terminals for connection units and customer interfaces
Control connections:
[21]
Dig. Input 1
(PTC input) (*)
[41]
+ 5V supply voltage
[40]
0V, GND
[41]
+ 5V supply voltage
[40]
0V, GND
[42]
+ 15V supply voltage
[74]
RS 485 interface: B (-)
[73]
RS 485 interface: A (+)
Termination resistor RS 485 On/Off
[02]
Signal relay (error)
[01]
Signal relay
[…] = Terminal No.
-B +B
-Br +Br
U V W
L1 L2 L3
Option
Customer unit
System connector M12 socket
Mechanical brake
External brake resistor
The polarity can be ignored.
(*) The digital inputs can be connected
with the internal 15 V or from the PLC
(7.5 – 33V DC). The data in "(...)"
represent the factory settings.
Fig. 3: Control terminals for connection unit SK TI 0/x-(C) for SK 300E
Customer side
Reference voltage +10 V (max. 10 mA)
[11]
AGND, 0V
[12]
Analog input -
[13]
Analog input +
[14]
Digital input 2 [Enable right]
[22]
Digital input 3 [Enable left]
[23]
Digital input 4 [Parameter set sw itching]
[24]
Supply voltage +15 V (max. 100 mA)
[42]
0...10V, 0/4…20mA
or
potentiometer:
2,0k
W...10kW
Floating contacts or
output of a PLC:
7,5...33V (low=0...3,5 V)
(Maximum terminal cross-section: 1,5 mm²)
Fig. 4: Control terminals for customer interface SK CU2-BSC-(C) for SK 300E
Customer side
Reference voltage +10 V (max. 10 mA)
[11]
AGND / 0V
[12]
Analog input 1
[14]
Analog input 2
[16]
Analog output 1
[17]
Digital input 2 [Enable right]
[22]
Digital input 3 [Enable left]
[23]
Digital input 4 [Parameter set switching]
[24]
Digital input 5 [fixed frequency 1]
[25]
Supply voltage +15 V (max. 100 mA)
[42]
0...10V, 0/4…20mA
or
potentiometer:
2,0k
W...10kW
Floating contact or
PLC output:
7,5...33V (low=0...3,5V)
(Maximum terminal cross-section: 1,5 mm²)