beautypg.com

2 control terminal connection, Control terminal connection – NORD Drivesystems MI0300 User Manual

Page 16

background image

Decentralised drive technology - from SK 300E to SK 200E

16

Migration Guide-GB-11.10.2012

3.2 Control terminal connection

SK 300E

Function / Meaning

SK 200E

Terminal bar

Terminal number

Terminal bar

Terminal number

SK 2x0E

SK 2x5E

SK TI 0/x-(C)

Control
connections

Connection unit

21

Digital input 1

Thermistor

SK TI4-x-2xx-x-(C)
control terminal bar

39

41

+ 5V supply voltage

38

40

0V, GND

40

42

+ 15V supply voltage

43

5

44

5

74

RS 485 interface B (-)

RJ12 control block

2

73

RS 485 interface A (+)

1

01

Signal relay (error)

SK TI4-x-2xx-x-(C)
control terminal bar

1

6

02

Signal relay

43

5

44

5

SK CU2-BSC-(C)

Customer interface

11

Reference voltage + 10V

SK TI4-x-2xx-x-(C)
control terminal bar

11

-

12

0V, AGND

12

-

13

Analog input -

SK TU4-IOE-(C)

I/O extension

4

14

Analog input +

3

22

Digital input 2

SK TI4-x-2xx-x-(C)
control terminal bar

22

23

Digital input 3

23

24

Digital input 4

24

42

Supply voltage + 15V

43

5

44

5

SK CU2-STD-(C)

Customer interface

11

Reference voltage + 10V

SK TI4-x-2xx-x-(C)
control terminal bar

11

-

12

0V, AGND

12

-

14

Analog input 1

14

-

16

Analog input 2

16

-

17

Analog output 1

SK TU4-IOE-(C)

I/O extension

7

9

7 (0V-A)

22

Digital input 2

SK TI4-x-2xx-x-(C)
control terminal bar

22

23

Digital input 3

23

24

Digital input 4

24

25

Digital input 5

SK TU4-IOE-(C)

I/O extension

19

11 (24V)

42

Supply voltage + 15V

SK TI4-x-2xx-x-(C)
control terminal bar

43

5

44

5

5

24V supply internal with SK 2x0E, external with SK 2x5E

6

Attention: This in not a potential-isolated relay output, but rather only a digital output!

7

if there is no SK CU4-MBR with SK 2x0E …-(C)

→use SK CU4-REL / part number 275271011