Terminal block x/ – digital i/o – NORD Drivesystems BU0530 User Manual
Page 38
Functional safety with NORD SK 500E frequency inverters
38
BU 0530 GB-3712
3.4.5
Details of the "Digital outputs" control connections
A digital output can be used to indicate the status of the "safe pulse block". It must be noted that this status
indication is not fail-safe.
Terminal block X/
– Digital I/O
Relevance
SK 500E
SK 505E
SK 510E
SK 511E
SK 515E
SK 520E
SK 530E
SK 535E
SK 540E
SK 545E
√
√
√
Terminals X7:
73
74
26
27
5
7
42
40
RS485 +
RS485 -
DIN6
DIN7
DOUT1
DOUT2
VO 15V
GND / 0V
Designation
Terminal Function
[factory setting]
Data
Description / wiring suggestion
Parameter
up to
SK 535E
SK 540E
and above
73
Data cable RS485
Baud rate
9600…38400Baud
Termination resistor
R=120
BUS connection parallel to RS485
on RJ12 plug
NOTE: The termination resistance of
DIP switch 1 (see RJ12/RJ45) can
also be used for terminal 73/74.
P503
P509
P503
P509
74
26
Digital input 6
[no function]
7.5...30V, R
i
=3.3k
As described for terminal block X5,
DIN1 to DIN5.
Not suitable for the evaluation of a
motor thermistor.
P425
P420 [-06]
27
Digital input 7
[no function]
P470
P420 [-07]
Only SK 54xE
Alternatively:
Output 5 (DOUT3)
[no function]
Digital output
15V, max. 20mA
max. 100k
load
With SK 54xE the digital input
(DIN7) can also be used as a digital
output (DOUT3).
If P434 [-05] and P420 [-07] are
parameterised with functions, a High
signal of the DOUT function results
in a High signal for the DIN function.
P434 [-05]
5
Output 3 (DOUT1)
[no function]
For evaluation in a control system.
The scope of functions corresponds
to that of the relay (P434).
P450
P434 [-03]
7
Output 4 (DOUT2)
[no function]
P455
P434 [-04]
Only SK 54xE
Alternatively:
Digital input 8
[no function]
7.5...30V, R
i
=3.3k
With SK 54xE the digital output
(DOUT2) can also be used as a
digital input (DIN3).
If P434 [-04] and P420 [-10] are
parameterised with functions, a High
signal of the DOUT function results
in a High signal for the DIN function.
P420 [-10]
42
15V supply voltage
output
15V
20%
Voltage supply for connection to the
digital inputs or the supply of a 10-
30V encoder
40
Reference potential
for digital signals
0V digital