7. Data Sheets
Translated extract from Data Sheet 01
of the EU Prototype Test Certificate PTB 07 ATEX 3053 X
for the three-phase motor, type 1MA7 163-4…
Rated values and data
This certificate applies for the following versions on condition that motors of this type only vary to an
insignificant extent from the tested sample with regard to the electrical and thermal load:
Star connection
Torque: 50
60
65.7
27
Nm
Power: 0.672
4.48
10
8.244
kW
Voltage: *)
53
200
400
400
V
Current: 14
17.6
18.9
17.6
A
Frequency: 5
25
50
100
Hz
Speed of rotation:
128
710
1455
2907
min
-1
Operating mode:
S1
Heat class
F
Delta connection
Torque: 50
60
65.7
56
Nm
Power: 0.672
4.48
17.663
17.3
kW
Voltage: *)
31
115
400
400
V
Current:
24.2 30.5 33.3 32.8
A
Frequency: 5
25
87
100
Hz
Speed of rotation:
128
710
2563
2946
min
-1
Operating mode:
S1
Heat class
F
*) Basic oscillation, measured at the motor terminals.
The voltage depends on the input voltage of the frequency inverter, the voltage drop at the filter
and over the motor supply cable and may not fall below the design value by more than 5%
according to IEC 60034 - 1 Range "A", even with minimum input voltage of the frequency inverter.
This must be taken into account for the design of the motor, the parameterisation of the inverter
(e.g. rev/f adaptation) and for the minimum input voltage of the inverter.
The maximum input voltage of the inverter is 500V.
Adaptation of the design voltage of the motor by means of the number of windings is permissible.
The rated current changes in inverse proportion to the rated voltage.
Sheet 1/3