beautypg.com

Data sheets – NORD Drivesystems B1092 User Manual

Page 29

background image

www.nord.com B1092-GB

-29-

7. Data Sheets

Translated extract from Data Sheet 01

of the EU Prototype Test Certificate PTB 07 ATEX 3050 X

for the three-phase motor, type 1MA7 106-4…

Rated values and data

This certificate applies for the following versions on condition that motors of this type only vary to an
insignificant extent from the tested sample with regard to the electrical and thermal load:

Star connection

Torque: 5

13.5

13.5

5.5

Nm

Power: 0.061

0.937

2.0

1.67

kW

Voltage: *)

40

200

400

400

V

Current: 2.4

4.4

4.4

3.4

A

Frequency: 5

25

50

100

Hz

Speed of rotation:

114.2

662

1424

2872

min

-1

Operating mode:

S1

Heat class

F

Delta connection

Torque: 5

13.5

12.7

12.7

Nm

Power: 0.061

0.937

3.38

3.86

kW

Voltage: *)

23

115

400

400

V

Current: 4.15

7.6

7.6

7.8

A

Frequency: 5

25

87

100

Hz

Speed of rotation:

114.2

662

2541

2896

min

-1

Operating mode:

S1

Heat class

F

*) Basic oscillation, measured at the motor terminals.

The voltage depends on the input voltage of the frequency inverter, the voltage drop at the filter
and over the motor supply cable and may not fall below the design value by more than 5%
according to IEC 60034 - 1 Range "A", even with minimum input voltage of the frequency inverter.
This must be taken into account for the design of the motor, the parameterisation of the inverter
(e.g. rev/f adaptation) and for the minimum input voltage of the inverter.

The maximum input voltage of the inverter is 500V.

Adaptation of the design voltage of the motor by means of the number of windings is permissible. The
rated current changes in inverse proportion to the rated voltage.

Sheet 1/3