Data sheets – NORD Drivesystems B1092 User Manual
Page 26
-26-
B1092-GB
www.nord.com
7. Data Sheets
Translated extract from Data Sheet 01
of the EU Prototype Test Certificate PTB 07 ATEX 3049 X
for the three-phase motor, type 1MA7 096-4…
Rated values and data
This certificate applies for the following versions on condition that motors of this type only vary to an
insignificant extent from the tested sample with regard to the electrical and thermal load:
Star connection
Torque: 3.0
9.1
9.1
3.6
Nm
Power: 0.034
0.604
1.34
1.08
kW
Voltage: *)
40
200
400
400
V
Current: 1.6
3.1
3.1
2.3
A
Frequency: 5
25
50
100
Hz
Speed of rotation:
108
630
1407
2854
min
-1
Operating mode:
S1
Heat class
F
Delta connection
Torque: 3
9.1
9.1
9.1
Nm
Power: 0.034
0.604
2.41
2.73
kW
Voltage: *)
23
115
400
400
V
Current: 2.8
5.4
5.4
5.7
A
Frequency: 5
25
87
100
Hz
Speed of rotation:
108
630
2518
2870
min
-1
Operating mode:
S1
Heat class
F
*) Basic oscillation, measured at the motor terminals.
The voltage depends on the input voltage of the frequency inverter, the voltage drop at the filter and
over the motor supply cable and may not fall below the design value by more than 5% according to
IEC 60034 - 1 Range "A", even with minimum input voltage of the frequency inverter. This must be
taken into account for the design of the motor, the parameterisation of the inverter (e.g. rev/f
adaptation) and for the minimum input voltage of the inverter.
The maximum input voltage of the inverter is 500V.
Adaptation of the design voltage of the motor by means of the number of windings is permissible. The
rated current changes in inverse proportion to the rated voltage.
Sheet 1/3