RELAY SETUP
Output confi guration:
1. Menu
2. Output
Confi
g.
3.
Alarm Relay 1 and Alarm Relay 2
4.
Choose Normally Open or Normally Closed
5.
Back to Output Confi g. Menu
6.
Back to Main Menu
7.
Back to Display Screen
Activate Relays:
8. Menu
9. Interfaces
10. Relay 1 and Relay 2 Output (Enable or Disable)
11. Back to Main Menu
12. Back to Display Screen
15
Alarm Relay 1 is mapped to Alarm High
and Alarm Relay 2 is mapped to Alarm
Low.
Threshold limits are set as a percentage
of the capacity of the sensor.
Pressing Reset on the IPM650 will reset
any alarm status.
Peak will fl ash on the IPM650 for an
active alarm high state, and Valley will
fl ash for an active low alarm state.
TIPS FOR ALARMS AND RELAYS