Default Settings
Input Range:
0 to +/-2 mV/V
Excitation Voltage: 10 VDC
Output Range:
+/-10 VDC, 4-20 mA
Connections
Pin
Wiring Code
1
+Excitation
(1)
2
+Signal
3
-Signal
4
-Excitation
(1)
5
Ground
6
Ground
7
Ground
8
Ground
9
Ground
Pin
Wiring Code
Cable Color Code
9
Power Supply
Red
8
Signal Out (Voltage)
Green
7
Ground
Orange
6
Ground
Black
5
Ground
N/A
4
Ground
N/A
3
Ground
N/A
2
Ground
Blue
1
Signal Out (Current)
(2)
White
Note: Do not connect the device to the power supply when the power
supply is already on!
(1) For 6 wire sensors connect +Sense to +Excitation and –Sense to –Excitation or Ground
(2) Only available with current output option
Male- Power Side
Female- Sensor Side