beautypg.com

Dwyer CPF User Manual

Page 3

background image

Body Size and Description
3/4˝ PVC-NPT connection
1-1/2˝ PVC-NPT connection
3˝ and 4˝ PVC-NPT connection
3/4˝ PVC-Flange connection
1-1/2˝ PVC-Flange connection
3˝ and 4˝ PVC-Flange connection

FLOWMETER

MAIN

PROCESS

LINE

BY-PASS

VALVE

FLOW

FIGURE 2: TYPICAL INSTALLATION-

VERTICAL LINE FOR LIQUID, GAS, OR VAPOR

SHUT-OFF

VALVES (2)

FIGURE 3: TYPICAL INSTALLATION-

HORIZONTAL LINE FOR LIQUID, GAS, OR VAPOR

SHUT-OFF

VALVES (2)

FLOWMETER

BY-PASS VALVE

FLOW

MAIN PROCESS LINE

Apply wrenches only on the flats or outer rims of the connection
ports. Avoid over-tightening (particularly with PVC or CPVC
models – no more than one turn after hand tight), and do not use
wrenches on other portions of the body or sight tube. When
solvent cementing in the vicinity of a meter with a
polysulfone sight tube, the tube should be removed until
the cement dries and fumes clear.

SURGE CHAMBERS & ACCUMULATORS: Flow meters are
more accurate and less likely to be damaged when the fluid flow
is smooth. If the meter must be installed on a line where
reciprocating pumps or compressors causing pulsation are
used, surge chambers or accumulators are strongly suggested
to damp the shock wave.

SIGHT TUBE ROTATION: On visual (the float disk is seen)
indication models with PLASTIC sight tubes, grasp the tube
firmly BY HAND near the body and twist until the scale faces the
desired direction. USE NO TOOLS!
On PLASTIC (PVC, CPVC) flow meters, the magnet is
encapsulated in the top of the float assembly to seal it from the
wetted system.

OPERATING LIMITS FOR SERIES PVF and CPF FLOWMETERS

Maximum Non-Shock Working Pressure, PSIG @ °F (bar @ °C)

70°F (21°C)
250 (17)
170 (11)
160 (11)
150 (10)
150 (10)
150 (10)

80°F (26°C)
255 (15)
150 (10)
150 (10)
150 (10)
150 (10)
150 (10)

100°F (37°C)
150 (10)
105 (7)
105 (7)
150 (10)
105 (7)
105 (7)

120°F (48°C)
90 (6)
65 (4)
65 (4)
65 (4)
65 (4)
65 (4)

140°F (60°C)
50 (3)
40 (2)
40 (2)
50 (3)
40 (2)
40 (2)

160°F (71°C)
N.R.
N.R.
N.R.
N.R.
N.R.
N.R.

180°F (82°C)
N.R.
N.R.
N.R.
N.R.
N.R.
N.R.

210°F (98°C)
N.R.
N.R.
N.R.
N.R.
N.R.
N.R.

Body Size and Description
3/4˝ CPVC-NPT connection
1-1/2˝ CPVC-NPT connection
3˝ and 4˝ CPVC-NPT connection
3/4˝ CPVC-Flange connection
1-1/2˝ CPVC-Flange connection
3˝ and 4˝ CPVC-Flange connection

70°F (21°C)
270 (19)
180 (12)
160 (11)
150 (10)
150 (10)
150 (10)

80°F (26°C)
270 (19)
180 (12)
160 (11)
150 (10)
150 (10)
150 (10)

100°F (37°C)
250 (17)
170 (11)
140 (10)
150 (10)
150 (10)
150 (10)

120°F (48°C)
200 (10)
145 (10)
125 (9)
135 (9)
135 (9)
135 (9)

140°F (60°C)
150 (10)
115 (8)
105 (7)
110 (8)
110 (8)
110 (8)

160°F
(71°C)
130 (9)
85 (6)
75 (5)
90 (6)
90 (6)
90 (6)

180°F (82°C)
80 (6)
50 (3)
50 (3)
70 (5)
70 (5)
70 (5)

210°F (98°C)
50 (3)
30 (2)
30 (2)
40 (2)
40 (2)
40 (2)

Note: N.R. = Not Recommended

Figure 1

Figure 2

F-23:TEMPLATE 10/27/09 4:07 PM Page 3

This manual is related to the following products: