1 qualified personnel, 2 special safety instructions, Qualified personnel – Dwyer MFS User Manual
Page 3: Special safety instructions

2.1 Qualified personnel
The personnel entrusted with installing, operating and maintaining the MFS have to be suitably qualified;
the required knowledge can be gained via training courses or appropriate on-the-job instruction. The
personnel must be familiar with the contents of these instructions, which need to be available to them at all
times.
The electrical connection should only be carried out by a fully qualified electrician.
All work has to be carried out in accordance with existing national regulations on accident prevention and
safety at work and with any internal regulations of the operator, even if they are not specified in these
instructions.
2.2 Special safety instructions
To avoid damage to the flow sensors and the monitored system, only use our flow sensors to measure
liquid flows.
Prior to installation, ensure whether the material of the flow sensor is suitable for the medium to be
measured.
In order to achieve accurate measurements, only use liquids with a minimum conductivity of 50 μS/cm.
Ensure that the maximum specified operating pressure is not exceeded.
Never remove a flow sensor from a pipe system under pressure.
Ensure that the maximum specified operating temperatures are not exceeded.
Select suitable measures to prevent the medium from freezing in the flow sensor.
Protect the flow sensor against external magnetic fields in the immediate vicinity, since these can impair
device functioning.
Caution: Voltage Hazard!
Always de-energize the system before connecting the connector cable.
It is prohibited to remove or make product labels or any other information attached to the equipment
indecipherable, otherwise all warranties and the responsibility of the manufacturer no longer apply.
Caution: Ensure that the maximum electrical load specified on the product label is never exceeded,
otherwise the electronic unit will be damaged.
Attention: Do not use MFS in processes in which a disturbance may possibly cause a risk of the health
and lives of others.
The customer is to verify the applicability of the product on the basis of our technical details and customer-
and applicationspecific test to proof the products fitness for ist purpose. By this checking, hazards and risks
are subrogated to the customer and our warranty expires.