SCOPE OF THE MANUAL
This manual contains information concerning the installation, operation and maintenance of Badger Meter magnetic drive
turbo meters To ensure efficient operation of the meters, the instructions given in this manual should be thoroughly read and
understood Retain the manual in a location where it is readily available for reference
SPECIFICATIONS
Maximum Operating Temperature
250 5° F (120 5° C)
Maximum Operating Pressure
150 psi (10 bar)
Optional: 300 psi (bronze), 250 psi (cast iron)
Accuracy Over Entire Range*
± 1 5%
Repeatability
0 5 or better
Connections
Round flange ASA or DIN
Body Materials
SS 316, bronze, cast iron
Rotor and Nose Cone Materials
Ryton
Head Assembly Materials
SS 316 or bronze
Straightening Vane Material
SS 316
Head Gasket Materials
Asbestos, Nitrile or Chloroprene
O-Ring Materials
EPR, Buna, Viton A
Bearing and Magnet Material
Ceramic
Spindle
SS 316
PRODUCT UNPACKING AND INSPECTION
Upon opening the shipping container, visually inspect the product and applicable accessories for any physical damage such
as scratches, loose or broken parts, or any other sign of damage that may have occurred during shipment
NOTE:
N
If damage is found, request an inspection by the carrier’s agent within 48 hours of delivery and file a claim with the
carrier A claim for equipment damage in transit is the sole responsibility of the purchaser
INSTALLATION
The procedures for installing Badger turbo meters are essentially the same for all meter sizes Any special instructions required
for the installation and/or electrical connection of meter-mounted or free-standing accessory devices such as registers, pulse
transmitters, valves and remote batch controllers will be provided as a supplement to this manual
Preliminary Considerations
• The Badger Meter 2" through 6" industrial turbo meters are designed for operation in HORIZONTAL piping arrangements
• If solid material is present in the liquid to be metered, a strainer may be required in the facility piping upstream of the
meter The 2", 3" and 4" meters require a strainer with 1/16" diameter holes and the 6" meter requires a strainer with 1/8"
diameter holes
• To permit periodic cleanout of the meter and to provide a convenient means of stopping fluid flow during maintenance, it
is recommended that a flushing system be incorporated into the facility piping arrangement
User Manual
Page 5