Warren Controls 5800 Series Compact Globe Control Valves User Manual
Page 3
3
Series 5800 5800_IOM_RevB_0413
0000
None
PosItioners:
BxP_
BLX Pneumatic
BxE_
BLX ElectroPneumatic
BxI_
BLX ElectroPneu. Intrn. Safe
BxX_
BLX ElectroPneu. Exp. Proof
BxF_
BLX ElectroPneu. Fail Freeze
76P_
Moore760 Pneumatic
76E_
Moore760 Electro-Pneumatic
P24_
Siemens PS2 Electro-Pneumatic
P2H_
Siemens PS2,3,4 Wire HART
P2P_
Siemens PS2 PROFIBUS PA
P2F_
Siemens PS2 FOUNDATION
FIELDBUS
PROXIMITY SWITCHES:
PX11
Mark 1 Series - 2 ea. SPDT
PX12
Mark 1 Series - 2 ea. SPDT
w/2k Pot.
PX13
Mark 1 Series - 2 ea. SPDT
w/4-20 Feedback
PX14
Mark 1 Series - 4 ea. SPDT
PX15
Mark 1 Series - 6 ea. SPDT
I/P’s Use with Diaphragm Only
MAP1
Type 500X I/P, 3-9 PSI
MAP2
Type 500X I/P, 9-15 PSI
MAP3
Type 500X I/P, 3-15 PSI
MAP4
Type 500X I/P, 1-17 PSI
MAP5
Type 500X I/P, 6-30 PSI
MAP6
Type 550X I/P, 0-30 PSI
MAP7
Type 550X I/P, 0-60 PSI-
For 15 or 5X only
MAP9
Type 950X I/P, 3-15 EXP
Actuator
Series
Action
Spring Range Handwheel
Positioners, I/P’s & Limit Switches
Air Filter
Regulators
Special
Options
ASCO
Solenoids
0
None
R
Reverse
Stem
Fail
Down
D
Direct
Stem
Fail Up
00
None
DIAPHRAGMS:
49
DL49
(49 Sq.In.)
84
DL84
(84 Sq.In.)
4X
DL49XR
8X
DL84XR
(84 Ext. Rng.)
for 58N only
15
DL115
(115 Sq.In.)
5X
DL115XR
CYLINDERS:
C1
4” Spring Fail
C2
6” Spring Fail
C3
8” Spring Fail
NOTE:
4X, 5X &
8X Only
in Xtra-High
Spring Range,
Reverse Acting
0
None
L
Low
3-9psi 49D; 84;
& 115
4-10psi 49R
F
Full
3-15psi 84 ; 115
5-14psi 49R;
4-13psi 49D
H
High
9-15 psi 84; 115
10-14 psi 49R
8-12 psi 49D
X
Xtra-High
DL49XR
DL84XR &
DL115XR
0
None
R
Reverse
D
Direct
NOTE:
Must match
action.
0
None
A
Type 300,
0-30 PSI,
5 micron
Filter
B
Type 300,
0-60 PSI
5 micron
Filter
C
Type 300,
0-120 PSI,
5 micron
Filter
D
Type 350SS,
0-100 PSI,
25 micron
Filter
ACCESSOrIES
0
None
120
VAC COILS
A
8320G184
3-Way Brass
B
8320G202
3-Way SS
J
8342G1
4-Way Brass
K
8342G701
4-Way SS
L
EF8320G184
3-Way EXP Br.
M
EF8320G202
3-Way EXP SS
V
EF8342G1
4-Way EXP Br.
W
EF8342G701
4-Way EXP SS
24
Vdc COILS
Z
8320G184
3-Way Brass
0
No Additions
L
w/Mech. Lmt Swtch’s
F
w/4-20 Feedback
B
w/Swtch’s & Feedbck
Note: L, F & B not
available for Bxl or BxX
4th digit spec.
F
Full Range Signal,
3-15 PSI or 4-20mA
L
Low of Split Range,
3-9 PSI or 4-12mA
H
High of Split Range,
9-15 PSI or 12-20mA
x
digit spec.
ACTUATOr
0
None
S
Special Opts
or Set-up
T
SS Tubing
G
SS Tagging
B
SS Tubing
and Tagging
Note: Standard
pneumatic tubing is
copper. SS tubing “T”
is optional.
SS tagging “G” (Two
lines, 24 characters/
line) is optional.
SS tubing and tagging
together “B” is
optional.
FAILURE MODES:
MODE ACTUATOr ACTION
Closed
Reverse
Open
Direct