beautypg.com

Revo REXN700-2 User Manual

Page 14

background image

- System Config

Multi-Camset

: Select On (User can use 4 configuration sets)/off

Video Analytics

: Select PVA mode. (Simple PVA/ PVA+)

Communication

: Configuration for RS-485.

Cam ID

: Select the camera ID (001 - 255).

Baud Rate:

Select serial communication speed (2400/4800/9600/19200).

Protocol

: RS-485 protocol. (Auto, FASTRAX/PELCO-D/PELCO-P)

Event Out

: Off, Text-Out, FxLink

Event Strings

: Select&edit sending strings for PVA/PVA+ Events.

NOTE:
* Text Out: Send event string through RS-485 line.

This function can work with IDIS DVR’s Text-in feature.

* FxLink: Send event to PC application.

- WPC (White Pixel Compensation)

: Compensation for defected pixel on CCD.

NOTE:
* While operating on WPC, Iris will be closed automatically if you using DC/IRIS Lens.

For manual lens, you have to block the lens hole.

Static/Auto: Automatic detecting for defected pixel & compensation.

Proceeding

: Doing detection for white pixel.

NOTE:
* If brightness is too high, stop the process and print message “Bright Too High”.
* This function can compensate max. 63 points.
* If detected points are more than 63 points, repeats this detection by changes conditions.
* If more than 63 point while changing conditions, stop the process, and print “Too Many WH

Pixels”

* User can stop the proceeding while on operating.

Done

: Complete white pixel detection.

View

Detected WP: Print detected pixel on screen.

Retry

: Restart WPC process.

Accept

: Store WPC result, and return to precious menu.

Dynamic
Automated white pixel compensation for not compensated pixel by static method,

No limits of compensation pixel number.
Select level (Low/Mid/High). Higher value setting is compensating more pixels.

NOTE:
* If the scene contains high frequency components can cause a loss.

Static/Manual

: Manual white pixel compensation by appointment method.

Move Finder window using 4-arrow keys.

Marker

: Expand finder window using digital zoom.

Move compensation pixel using 4-arrow keys.

Register

: Adding compensation pixel.

NOTE:
* Registered points are more than 63 points, print “Memory Full” and stops action.

Marker

: Use this if user sees other points.

Finder

: Use this when you need to move finder screen.

UnDo

: Cancel the registered point.

Done

: Return to previous menu.

14