Parameters to be saved – KYORITSU 6305 Quick Manual User Manual
Page 26

−
25 −
KEW6305
KEW6305
Parameters to be saved
●
Parameters to be saved
The table below shows the parameters to be saved corresponding to each measurement range.
(Parameters to be saved are different depending on wiring systems.)
Manual saving : parameters in column 1 only
(except for max/ min/ avg of each parameter)
Auto-saving
: all parameters in column 1 & 2
Parameters to be saved
1
Voltage
(RMS)
Vi
: voltage of each phase
Vi max : max. Vi values
Vi min : min. Vi values
Vi avg : avg. Vi values
Current
(RMS)
Ai
: current of each phase
Ai max : max. Ai values
Ai min : min. Ai values
Ai avg : avg. Ai values
Active power
P
: total active power
Pi
: active power of each phase
P max : max. P value
Pi max : max. Pi values
P min : min. P value
Pi min
: min. Pi values
P avg : avg. P value
Pi avg
: avg. Pi values
Reactive power
Q
: total reactive power
Qi
: reactive power of each phase
Q max : max. Q value
Qi max : max. Qi values
Q min : min. Q value
Qi min
: min. Qi values
Q avg : avg. Q value
Qi avg
: avg. Qi values
Apparent power
S
: total apparent power
Si
: apparent power of each phase
S max : max. S value
Si max : max. Si values
S min : min. S value
Si min
: min. Si values
S avg : avg. S value
Si avg
: avg. Si values
Power factor
PF
: power factor of whole system PFi
: power factor of each phase
PF max : max. PF value
PFi max : max. PFi values
PF min : min. PF value
PFi min : min. PFi values
PF avg : avg. PF value
PFi avg : avg. PFi values
Frequency
f
: frequency of V1
f max : max. f value
f min
: min. f value
f avg
: avg. f value
Neutral
current
In
: current on neutral line
In max
: max. In value
In min
: min. In value
In avg
: avg. In value
2
Active energy
(consumption)
(regenerating)
(overall)
+WP
: total active energy (consumption)
+WPi
: active energy (consumption) of each phase
-WP
: total active energy (regenerating)
-WPi
: active energy (regenerating) of each phase
#WP
: total active energy (overall)
#WPi
: active energy (overall) of each phase
Apparent
energy
(consumption)
(regenerating)
(overall)
+WS
: total apparent energy (consumption)
+WSi
: apparent energy (consumption) of each phase
-WS
: total apparent energy (regenerating)
-WSi
: apparent energy (regenerating) of each phase
#WS
: total apparent energy (overall)
#WSi
: apparent energy (overall) of each phase
Reactive energy
(consumption) +WQ
: total reactive energy (consumption)
Demand value #DEM : total demand value
#DEMi : demand value of each phase
TARGET : target demand value
* i = 1, 2, 3
where, “max.” and “avg.” mean maximum and average values during an interval.