2 insulation diagnosis tests – KYORITSU 3128 User Manual
Page 51
KEW3128
47
KEW3128
6. Measurement
6. 2 Insulation Diagnosis Tests
This instrument can measure and perform following items as a part of
Insulation resistance Test.
- Insulation Resistance (IR)
- Polarization Index (PI)
- Dielectric Absorption Ratio (DAR)
- Dielectric Discharge (DD) *Auto-testing
- Step Voltage Test (SV)
Measurement Mode
Function
Insulation
Resistance (IR)
Performs normal insulation resistance
measurements (consistent measurements)
Polarization Index(PI)
Measures resistances twice and calculates
polarization index automatically.
(
default value: 1 min, 10 min)
Dielectric Absorption
Ratio (DAR)
Measures resistances twice and calculates
dielectric absorption ratio automatically.
(
default value: 15 sec, 1 min)
Dielectric Discharge
(
DD)
Calculates dielectric discharge based on the
measured capacitance of the measured object and
residual current values after testing.
Step Voltage Test(SV)
Increases the set voltage by 20% every time
when pre-set time comes.