Display:
Liquid crystal display
Bar graph: Max. 41points
DAR/PI value: 9.99
Time: 99:59
●
Low battery warning: Battery mark display (in 4 levels)
●
Overrange indication: “OL” mark appears at insulation resistance
range and “Hi” mark at voltage range.
●
Auto-ranging:
Range shifts to upper range : 1000 counts
Range shifts to lower range : 80 counts
(Only at the insulation resistance range)
●
Auto-power-off:
Power off function operates in 10 min. after
the last switch operation.
●
Used location:
altitude 2000 m or less
●
Temperature & humidity range (guaranteed accuracy):
23ºC±5ºC/Relative humidity 85% or less
(no condensation)
●
Operating temperature & humidity range:
0ºC to 40ºC/Relative humidity 85% or less
(no condensation)
●
Storage temperature & humidity range:
-20ºC to +60ºC/Relative humidity 75% or less
(no condensation)
●
Overload protection: Insulation resistance range: AC1200V/10sec.
Voltage range: AC720V/10sec.
●
Withstand voltage:
AC6720V(50/60Hz)/5sec.
(Between electrical circuit and enclosure)
●
Insulation resistance: 1000MΩ or more/DC1000V
(Between electrical circuit and enclosure)
●
Dimension:
208(L)×225(W)×130(D)mm
(Hard case 380(L)×430(W)×154(D)mm)
●
Weight:
4kg approx. (including battery)
Total 8kg approx. (including accessories)
●
Power source:
Rechargeable battery
12V5Ah Lead acid batteries (PXL12050) or equivalent.
●
Power Adapter
Output:DC15V(15VA)
for recharging
Input:100-240V 50/60Hz