Ufc 030 hart menu tree pdm parameter table – KROHNE UFC 030 HART User Manual
Page 19

KROHNE Messtechnik GmbH & Co. KG · Ludwig-Krohne-Str. 5 D-47058 Duisburg
19/20
Tel.: 0203-301 0 Fax: 0203-301 389 · e-mail: [email protected]
Supplementary Installation and Operating Instructions UFC 030 HART
HC275, FC375, AMS, PDM
Operation Unit
• Tag
• Descriptor
• Message
Measuring Limits
Device
Identification
Volume Flow
• Upper Sensor Limit
Rd
• Minimum Span
Rd
Heat Flow
• Upper Sensor Limit
Rd
• Minimum Span
Rd
VOS
• Upper Sensor Limit
Rd
• Lower Sensor Limit
Rd
• Minimum Span
Rd
Operation Parameter
5
• Manufacturer
Rd
• Model Number
Rd
• Serial Number
Rd
• µP1 HW No.
Rd
• µP2 SW No.
Rd
• FE HW No.
Rd
• DSP HW No.
Rd
• DSP SW No.
Rd
• Version
Rd
• Meter Size Table
Opt
• Enable reset
Available I/O
Opt
• SI Units
• Pulse Output
• Current Output
• Digital Input
• Analog IO module
• HART Interface
Rd
• FF Interface
Rd
• PA Interface
Rd
• MODIS Version
Rd
• Time/log Module
Rd
HART
• Manufacturer
Rd
• Device Type
Rd
• HART Device ID
Rd
• Universal Revision
Rd
• Field Device Revision
Rd
• Software Revision
Rd
• Hardware Revision
Rd
• Date
• Final Assembly No.
• Sensor Serial No.
Sensor
Opt
• Dead Time
• Trigger Select
• Trigger Level 1
• Trigger Margin
• Sensor Frequency
Identification
Operation Unit
Device
-----------------------------------
Input
Measuring Limits
Operation Parameter
Sensor
Version
Analog Input
Opt
Measuring Path
Opt
Plausibility Filter
-----------------------------------
Output
Current Output I
Pulse Output P
Opt
-----------------------------------
Human Interface
Local Display
Display Formats
5
UFC 030 HART Menu Tree PDM
Parameter Table
Version
Opt
• Converter Function
• Temperature Units
Opt
• Input 1 4mA
Opt
• Input 1 20mA
Opt
• Pressure Units
Opt
• Input 2 4mA
Opt
• Input 2 20mA
Opt
• K0
Opt
• K1
Opt
• K2
Opt
• Density 15
Opt
• Heat Flow Units
Opt
• Full Scale
Opt
Designations:
Opt
Optional, dependent on device
implementation / configuration
Rd
Read-only
Loc
Local PDM, affects only PDM views
• Flow Units
• Full Scale
• Zero Value
• Master TC
• GK Value
• Flow Direction
• VOS Min/Max Units
• Min VOS
• Max VOS
• L.F. Cutoff
• Cutoff on
Opt
• Cutoff off
Opt
Input
Input
...
Measuring Path
Opt
• Path 1 active ...
• Weight 1 ...
• Length 1 ...
• Zero Value 1 ...
• Time Window Start
• Time Window End
Plausibility Filter
• Error Limit
• Counter Decrement
• Counter Limit
Process Connection
• Meter Size Table
Opt
• Meter Size Units
Opt
• Meter Size
Analog Input Calibration
Opt
• Input 1 0mA
• Input 1 20mA
• Input 2 0mA
Opt
• Input 2 20mA
Opt
KROHNE UFC030 HA 45e80101 (4/5)
09.04