TECHNICAL DATA

8

31

OPTIFLUX 2070

www.krohne.com

04/2008 • 4000243601

IFC 070 flow converter

Functions

Flow direction

Bi-directional measurement

Low flow cut-off

Selectable

Design

Display

8 digits LCD

Status indication for battery, diagnostics

Units

m

3

, US Gallons

m

3

/h, USGPM

Cable connections

Standard

2x M20 x 1,5

Optional

1/2" NPT, PF 1/2

Materials

Converter housing

Die-cast aluminium (polyurethane coated)

In- and output

Outputs

2 passive pulse outputs for remote totalising

f ≤ 500 Hz; I ≤ 10 mA; U: 5...24 VDC (P ≤ 100 mW)

2 passive status outputs

I ≤ 10 mA; U: 5...24 VDC (P ≤ 100 mW)

Power supply

Standard

2 lithium batteries (D-cell), typical lifetime 6 years.

Alarms

Pre-alarm 1 year before battery depletion and final alarm

Battery replacement

Possible without loss of totaliser data

Approvals

Protection class

IP 66/67 (NEMA 4X/6)