3

INSTALLATION

14

OPTIFLUX 2070

www.krohne.com

04/2008 • 4000243601

3.5.10 Grounding

3.6 Installation

Here you find the maximum pressure and torques for the flowmeter. All values are theoretical
and calculated for optimum conditions and use with carbon steel flanges.

Figure 3-12:

The grounding of the flowmeter

1

Metal pipelines, not internally coated. Grounding without grounding rings!

2

Metal pipelines with internal coating and non-conductive pipelines. Grounding with grounding rings!

3

Grounding rings

CAUTION!
The grounding of the flowmeter provides a stable and accurate measurement.

Nominal size

DN [mm]

Pressure

rating

Bolts

Max. torque [Nm]

Polypropylene

Hardrubber

50

PN 40

4 × M 16

55

31

65

PN 16

4 x M 16

51

42

80

PN 40

8 × M 16

47

25

100

PN 16

8 × M 16

39

30

125

PN 16

8 x M 16

53

40

150

PN 16

8 × M 20

68

47

200

PN 10

8 × M 20

-

68

250

PN 10

12 x M 20

-

65

300

PN 10

12 x M 20

-

76

350

PN 10

16 x M 20

-

75

400

PN 10

16 x M 24

-

104

450

PN 10

20 x M 24

-

93

500

PN 10

20 x M 24

-

107

600

PN 10

20 x M 27

-