Operation – KROHNE OPTIFLUX 2070 EN User Manual
Page 25
OPERATION
6
25
OPTIFLUX 2070
www.krohne.com
04/2008 • 4000243601
56
Status output 2
Battery pre
warning
0
0 = off, 1 = on
Active 1 year before empty
battery
57
Status output 2
Battery final
warning
0
0 = off, 1 = on
Active at low battery
58
Status output 2
Counter
overrun
0
0 = off, 1 = on
After 99999999 counter starts at
zero
59
Status outputs
pulsating
1
0 = off, 1 = on
Pulse of 1 ms every second
60
Show Flow
Rate
0
0 = off, 1 = on
-
61
Show Counter
Forward
0
0 = off, 1 = on
-
63
Show Counter
Reverse
0
0 = off, 1 = on
-
65
Show Net
Counter
1
0 = off, 1 = on
-
66
All counters
reset
88888
Set to 00000
After reset display value is back
to 88888
Confirm with “>” for 3 seconds
71
Counters
Run/Stop
1
0 = stop, 1 = run
72
All Errors
Reset
0
Set to 1
After reset display value is back
to 0
Confirm with “>” for 3 seconds
73
Battery type
1
1 = single, 2 = dual, 2 = external
External battery is in preparation
74
Battery pack
capacity
xx
Value in Ah
-
75
Reset battery
life time
counter
0
Set to 1
After reset display value is back
to 0
Confirm with “>” for 3 seconds
76
Load default
settings
0
Set to 1
After reset display value is back
to 0
Confirm with “>” for 3 seconds
77
Fiscal metering
verification
reading
0
0 = off, 1 = on
For legal verification only
Software version 2.0.0
Menu
No.
Description
Display
default
Selection list
Remarks