TECHNICAL DATA

58

OPTIMASS 6000

www.krohne.com

07/2014 - 4001894003 - MA OPTIMASS 6000 R03 en

6.5.5 Purge port option

Dimensions

6.5.6 Burst discs

If the meter has been ordered with a burst disc, it will be supplied with the disc fitted. The failure
pressure of the disc is 10 barg at +20°C / 145 psig at +68°F.

mm

S08

S10

S15

S25

S50

S80

S100

S150

S200

S250

A

70

110

145

150

205

220

345

600

800

B

32

45

57

60

85

100

160

140

inches

S08

S10

S15

S25

S50

S80

S100

S150

S200

S250

A

2.7

4.3

5.7

5.9

8.1

8.7

13.6

23.6

31.5

B

1.3

1.8

2.2

2.4

3.3

3.9

6.3

5.5

CAUTION!
The fitted burst disc will be suitable for the flow rates and process conditions specified on the
original order. If the process conditions alter in any way, it is recommended that you contact the
manufacturer for advice regarding suitability.

If the process product is hazardous (in any way) it is recommended that an exhaust tube is
connected to the NPT male thread of the burst disc and the pipe routed so that the process
product can be discharged to a safe area. Use a tube with a diameter large enough AND routed in
such a way, so that pressure cannot build up in the meter case.

INFORMATION!
For gas applications, the burst disc must be specified at the time of ordering.

MA_OPTIMASS_6000_en_140717_4001894003_R03.book Page 58 Thursday, July 17, 2014 3:27 PM