Technical data – KROHNE OPTIMASS 6000 EN User Manual
Page 32
6
TECHNICAL DATA
32
OPTIMASS 6000
www.krohne.com
07/2014 - 4001894003 - MA OPTIMASS 6000 R03 en
Maximum flow rates
Maximum flow rates
Maximum flow rates
Maximum flow rates
All meters
150% of nominal flow rate
Ambient temperature
Ambient temperature
Ambient temperature
Ambient temperature
Compact version with Aluminium
converter
-40...+65°C / -40…+149°F
Compact version with Stainless Steel
converter
-40...+55°C / -40…+131°F
Remote versions
Standard temperature range: -40...+65°C / -40…+149°F
Cryogenic temperature range: -20...+65°C / -4…+149°F
Hazardous Area versions
Refer to temperature limits
Process temperatures
Process temperatures
Process temperatures
Process temperatures
Standard temperature range (flange connections)
Safe area
-70…+230°C / -94…+446°F
Hazardous area
-50…+230°C / -58…+446°F
High temperature range
-50…+400°C / -58…+752°F
Cryogenic temperature range
-200…+40°C / -328…+104°F
Standard temperature range (hygienic connections)
Safe area
-70…+150°C / -94…+302°F
Hazardous area
-50…+150°C / -58…+302°F
Nominal pressure at 20
Nominal pressure at 20
Nominal pressure at 20
Nominal pressure at 20°C / 68
C / 68
C / 68
C / 68°F
F
F
F
Measuring tube
Measuring tube
Measuring tube
Measuring tube
SS 316 / 316L
Hastelloy® C22 / S31803
FM / PED 97/23/EC
-1…100 barg / -14.5…1450 psig
-1…200 barg / -14.5…2900 psig
CRN / ASME B31.3
-1…100 barg / -14.5…1450 psig
Pending
Outer casing burst pressure
Outer casing burst pressure
Outer casing burst pressure
Outer casing burst pressure
08
≈ 100 barg
10
15
25
50
≈ 70 barg
80
100
≈ 10 barg
150
200
250
If the process temperature is higher than 20°C / 68°F, the burst pressure will be lower. For more information please
contact the manufacturer.
Fluid properties
Fluid properties
Fluid properties
Fluid properties
Permissible physical condition
Liquids, gases, slurries
Permissible gas content (volume)
Contact manufacturer for information.
Permissible solid content (volume)
Contact manufacturer for information.
Protection category (acc. to EN 60529)
IP 67, NEMA 4X
Installation conditions
Installation conditions
Installation conditions
Installation conditions
Inlet / outlet runs
None required
MA_OPTIMASS_6000_en_140717_4001894003_R03.book Page 32 Thursday, July 17, 2014 3:27 PM