Technical data, 5 dimensions and weights – KROHNE OPTIMASS 6000 EN User Manual
Page 42
6
TECHNICAL DATA
42
OPTIMASS 6000
www.krohne.com
07/2014 - 4001894003 - MA OPTIMASS 6000 R03 en
Notes
• The maximum operating pressure will be either the flange rating or the measuring tube
rating, WHICHEVER IS THE LOWER!
WHICHEVER IS THE LOWER!
WHICHEVER IS THE LOWER!
WHICHEVER IS THE LOWER!
• The manufacturer recommends that the seals are replaced at regular intervals. This will
maintain the hygienic integrity of the connection.
6.5 Dimensions and weights
6.5.1 Flanged versions
Meter weights
The weights shown are for meters fitted with PN40 flanges. Smaller or larger flange sizes will
affect the overall weight. For further information, please contact the manufacturer.
kg
S08
S10
S15
S25
S50
S80
S100
S150
S200
S250
Aluminium
(compact)
9.3
10.1
12.9
23.5
29.4
58.9
94.3
193.6
443.6
911.2
Stainless Steel
(compact)
15.2
16
18.8
29.4
35.3
64.8
100.2
199.5
449.5
917.1
Aluminium
(remote)
5.8
6.6
9.4
19.9
25.9
55.4
90.8
190.1
440
907.6
Stainless Steel
(remote)
6.6
7.3
10.2
20.7
26.6
56.1
91.5
191.5
440.8
908.4
Heating jacket add
3.1
4.5
7
7.9
12.7
15.7
27.6
N/A
lbs
S08
S10
S15
S25
S50
S80
S100
S150
S200
S250
Aluminium
(compact)
20.5
22.3
28.4
51.8
64.8
129.8
207.9
426.8
978
2008.8
Stainless Steel
(compact)
33.5
35.3
41.4
64.8
77.8
142.9
220.9
440.7
991
2021.9
Aluminium
(remote)
12.8
14.5
20.7
43.9
57.1
122.1
200.2
419.1
970
2001
Stainless Steel
(remote)
14.55
16.1
22.5
45.6
58.6
123.7
201.7
422.2
971.8
2002.7
Heating jacket add
6.8
9.9
15.4
17.4
28
34.6
60.8
N/A
MA_OPTIMASS_6000_en_140717_4001894003_R03.book Page 42 Thursday, July 17, 2014 3:27 PM